Torqeedo Ultralight Error Codes

Error Code Description & Possible Fix
E02 Motor overheated Motor can be used again after a short wait (about 10 minutes). Contact Torqeedo Service.
E03 Motor tipped during operation Motor can be used again after tipping it down and pressing on/ off.
E04 Move command with tipped motor The engine can be driven again after tilting from the stop position.
E05 Motor/propeller blocked Separate motor cable from battery. Loosen blockage and turn propeller one revolution by hand. Insert motor cable again.
E06 Voltage in the motor too low Low battery charging status. Motor can be used again slowly from the stop position.
E07 Motor over current Continue at low output. Contact Torqeedo Service.
E08 Circuit board overheating Motor can be used again after a short wait about 10 minutes). Contact Torqeedo Service.
E21 Remote throttle calibration defective • Re-calibrate: Press “cal” button for 10 seconds. • The display shows “cal up”: Press remote throttle lever forward to full gas then press the “cal” button. • The display shows “cal stp”: Return remote throttle lever to central (stop) position then press the “cal” button. • The display shows “cal dn”: Press remote throttle lever reverse to full gas then press the “cal” button.
E22 Magnetic sensor defective Re-calibrate (refer to E21).
E23 Value range false Re-calibrate (refer to E21).
E30 Motor communication error Check the motor cable’s plug-in connection. Check the motor cable for damage.
E32 Remote throttle communication error Check the remote throttle‘s connections. Check the cable.
E33 Internal error • Overcurrent of 5V bus/-USB supply – > Check cable of tiller/remote throttle, remove additional devices such as TorqTrac and USB connection, and switch system on/off. • Error is displayed immediately after turning on the battery and can be reset by the tiller / the remote throttle. -> Parameter error, error in the EEPROM. Contact the Torqeedo Service Center.
E36 Overvoltage battery/ engine For external drive (towing the boat, sailing, operating with another engine), the propeller is to be taken out of the water. If the error occurs during/after charging the battery contact the Torqeedo Service Center.
E41 Excessive charging voltage / charging current too high If the error occurs despite the use of a Torqeedo power supply, contact the Torqeedo Service Center.
E42 Power fuse defective Battery only starts when charging cable is plugged in. Contact Torqeedo Service Center.
E43 Battery empty Charge battery. Motor can be used again slowly from the stop position.
E45 Battery overcurrent Switch motor off and on again. If this error occurs the battery status indicator and range display can no longer operate until the battery has been fully charged again.
E46 Battery operating tempe- rature fault Battery cells outside operating temperature between -20°C and +60°C (-4°F and +140°F). The motor can be used again when the temperature has stabilized.
E48 Charging temperature error Allow battery to cool; charging will continue when the cell temperature is between 0°C and +45°C (32°F and 113°F).
E49 Battery is exhaustively discharged Contact Torqeedo Service Center. Other error codes Faulty Contact Torqeedo Service and notify them of the error code. Nothing displayed/ no flashing during charging Battery does not charge Contact Torqeedo Service Center.

The Plastic Hull is not affiliated with Torqeedo. Please contact Torqeedo service_usa@torqeedo.com regarding warranty or repair service.

Written by Matt Trucks